HY-SW1081-AQ / What are the specifics Hybrone Smart Air Quality Sensor ?

Modified on Mon, 3 Jun at 4:13 PM


About the Hybrone Smart Air Quality Sensor


HY-SW1081-AQ








Features


1. Large LED display shows CO2, temperature, humidity, date and time.

2. 30 degree tilt angle makes the display easier to see and read. 

makes it easier.

3. Indoor air quality level indicator: Good, Normal and Poor.

4. Stable NDIR sensor for CO2 detection.

5. Visible and audible CO2 warning alarm.

6. OTK (Automatic Basic Calibration) CO2 calibration.

7. Maximum or minimum CO2 level, temperature, humidity alarm setting 

function.

8. Silent Mode Setting.



Box Contents



Technical Specifications


Power Supply
AC Adaptor Input : AC 100~240V - Output : DC5V/1A Micro USB
Replacement Battery
Lithium Battery
CO2 Sensor Type
Non-dispersive infrared (NDIR) sensor
CO2 Sensor Lifetime

Maximum 10 years

Network Communication
WiFi 2.4 GHz
Operating Temperature
-10°C to 50°C
Working Ambient Humidity
10% to 95% (non-condensing)
Installation Location
 Wall mount or table stand type
CO2 Measurement Range
400-5000ppm
CO2 Accuracy

100 ppm or 10% of measured values,whichever higher than

Air Quality / CO2 Concentration

Good: <1000ppm Normal: 

1000~2000ppm Bad: >2000ppm (Values adjustable)

Alarm Triggering
Poor: >2000ppm (Values adjustable)
Dimensions

90x90x26mm (without feet)


Tips


Please read the following before using the device for the first time follow the instructions carefully and do not allow the use of electronic devices follow all warnings, even if you are familiar with them.

1. To protect the components inside the device, do not direct the monitor store and operate in a dry place out of sunlight.

2. Before using the device for the first time, place it in a well-ventilated (like a well-ventilated living room).

3. To make sure the device is more stable. The device has 24 It is recommended to start working after an hour of charging.

4. Do not cover the device and do not allow air to circulate, especially when the monitor is active. Do not cover the inputs.

5. The device is not waterproof, so do not drain water and other liquids from the monitor keep away.

6. Do not insert sharp, flammable or metal objects into the air intakes, this may cause electric shock or burns.

7. Power via micro usb cable and AC adapter must be provided; the internal, on-board battery is an emergency power supply only is used for. If the device is dropped or otherwise damaged it should no longer be used.

8. OTK Calibration: For the OTK to function properly, the CO2 levels continuously for at least 7 days (power on). During this time it will record the lowest CO2 level and use this as a baseline of 400 ppm for future readings will adjust it. Therefore, when using ABC calibration, it is recommended that the device 7 exposure to fresh air at least once during the day is critical is of importance. It is important to note that ABC is always located not suitable for application in the field.

NOTE: Do not hold the device to your face as your breath will affect the CO2 level don't keep it close.


 