About the Hybrone Smart Smoke Detector
HY-SW1041-SD
WARNING This user manual provides information about the smoke detector you have contains important information. If you want to use this smoke detector use, you should read this manual (or a copy of it) before leave it with the user.
Statements
1. Figures are shown for reference only.
2. While technology is constantly evolving, the use of practical operation guidelines, the final interpretation rights belong to the manufacturer.
Photoelectric sensors are usually installed better at detecting fires that burn slowly for hours effective.These fires are often caused by fire risks such as smoking ofmaterials,items such as armchairs or beds it starts to catch fire easily.
Ionization sensors are a fast-depleting, flammable material that quickly consumes combustible materials and generally better at detecting fast-spreading flaming fires are effective. Sources of these fires include flammable liquids or burning paper in the waste container.
However, both types of sensors provide sufficient detection for both types of fireprovides. Both slow-moving fires and fast-growing if you want early detection of fires, both photoelectric and combining both ionization detection technologies in a single unit you should prefer smoke detectors.
Box Content
Technical Specifics
Operating Voltage | 3V (1x CR123A/ CR17335 Lithium Battery) |
Visual Alarm Signal | Red LED Indicator |
Sound Level | Sound Level: ≥85dB/3m |
Operating Temperature | 0°~+55° |
Operating Humidity | ≤95%RH (non-condensing) |
Dimensions | Φ86 x H34.5 mm |
Mounting | Wall mount or ceiling mount |
Battery Life | 5 Years |
Long Performance with Replaceable Battery
Replaceable lithium battery extends the lifetime of the smoke detector helps to prolong it.
Status Indicator (LED)
Power the smoke alarm by flashing approximately every 53 secondsand that it is operating normally.
Low Battery Warning
A warning tone sounds every 53 seconds when the battery is low.
Silent Operation Mode (Alarm Pause)
In a situation where there is no risk of fire, the smoke detector as the start of an alarm.Test when the alarm state is active the silent operation of the smoke detector by pressing the button once can be provided. The red light on the detector will flash every 10 seconds blinks to remind you that it is in silent mode. 10 minutes then silent mode is removed and audible if the fire condition is still present the alarm warning continues. With smoke detector mobile application can also be set to silent mode.
Test Function
To check that the smoke detector is working normallythe test button must be pressed periodically
Audible & Visual Alarm Signals
When the smoke detector detects a fire situation, theloud alarm siren with red light flashing rapidlywill give a warning at short intervals.
Was this article helpful?
That’s Great!
Thank you for your feedback
Sorry! We couldn't be helpful
Thank you for your feedback
Feedback sent
We appreciate your effort and will try to fix the article