HY-SW1041-SD / What are the specifics Hybrone Smart Smoke Detector ?

Modified on Mon, 3 Jun at 4:21 PM


About the Hybrone Smart Smoke Detector


HY-SW1041-SD





WARNING

This user manual provides information about the smoke detector you have contains important information. If you want to use this smoke detector use, you should read this manual (or a copy of it) before leave it with the user.

Statements


1. Figures are shown for reference only.

2. While technology is constantly evolving, the use of practical operation guidelines, the final interpretation rights belong to the manufacturer.



Photoelectric sensors are usually installed better at detecting fires that burn slowly for hours effective.These fires are often caused by fire risks such as smoking ofmaterials,items such as armchairs or beds it starts to catch fire easily.



Ionization sensors are a fast-depleting, flammable material that quickly consumes combustible materials and generally better at detecting fast-spreading flaming fires are effective. Sources of these fires include flammable liquids or burning paper in the waste container.


However, both types of sensors provide sufficient detection for both types of fireprovides. Both slow-moving fires and fast-growing if you want early detection of fires, both photoelectric and combining both ionization detection technologies in a single unit you should prefer smoke detectors.


Box Content



Technical Specifics


Operating Voltage
3V (1x CR123A/ CR17335 Lithium Battery)
Visual Alarm Signal
Red LED Indicator
Sound Level
Sound Level: ≥85dB/3m
Operating Temperature
0°~+55°
Operating Humidity
≤95%RH (non-condensing)
Dimensions
Φ86 x H34.5 mm
Mounting
Wall mount or ceiling mount
Battery Life
5 Years


Long Performance with Replaceable Battery

Replaceable lithium battery extends the lifetime of the smoke detector helps to prolong it.

 

Status Indicator (LED)

Power the smoke alarm by flashing approximately every 53 secondsand that it is operating normally.

 

Low Battery Warning

A warning tone sounds every 53 seconds when the battery is low.

 

Silent Operation Mode (Alarm Pause)

In a situation where there is no risk of fire, the smoke detector as the start of an alarm.Test when the alarm state is active the silent operation of the smoke detector by pressing the button once can be provided. The red light on the detector will flash every 10 seconds blinks to remind you that it is in silent mode. 10 minutes then silent mode is removed and audible if the fire condition is still present the alarm warning continues. With smoke detector mobile application can also be set to silent mode.

 

Test Function

To check that the smoke detector is working normallythe test button must be pressed periodically

 

Audible & Visual Alarm Signals

When the smoke detector detects a fire situation, theloud alarm siren with red light flashing rapidlywill give a warning at short intervals.